Recent NAIMA testing shows failure of elastomeric duct liner products. Read the complete study results here.
Article content provided by Johns Manville.
NAIMA performed independent testing on fiberglass and elastomeric duct insulation products since there are stringent FSI and SDI limits for those products located in plenum spaces, and here are the results.
The purpose of this test was to observe the flame spread along a sample to determine the relative burning behavior of the material. There are several ASTM E84 references in the International Mechanical Code (IMC) that set limits to the Flame Spread Index (FSI) and Smoke Developed Index (SDI) in specific applications. Most relevant for this study, the IMC sets stringent FSI and SDI limits for duct insulation products located in plenum spaces to ensure occupant safety from dangerous fire spread and smoke in the event of fire.
NAIMA developed a plan to systematically conduct third-party testing of both elastomeric and fiberglass duct liner products at multiple Intertek Laboratories. The engagement of a third-party test laboratory as a part of this test program ensures that the ASTM E84 and E2231 procedures are followed without individual manufacturers guiding product selection or configuration of the test apparatus. The results of the test program are listed below and show a systemic issue with the performance of elastomeric products.
The results of this study are not intended to make claims on individual elastomeric products, but to display the issue at large. However, company claims should be investigated further based on the performance seen in this test program. View the study in its entirety here.
Actions Designers and Specifiers Can Take Today
Visit the Johns Manville website.
Have a question for Johns Manville? Contact Johns Manville here.
Johns Manville supports contractors with productivity-enhancing and performance-enhancing mechanical products, including duct, pipe, and building insulations.
Feb 29, 2024 — Products & Services Update
May 21, 2025 - Transverse joint leakage has long challenged ductwork performance. Iowa Precision’s Pro-Fabriduct now features full-width seams to reduce leaks and enhance system efficiency.
May 21, 2025 - Discover the ultimate HVAC insulation solutions with Johns Manville's comprehensive Product Selection Guide! Elevate your projects with top-tier duct board and liner insulation, designed for superior thermal and acoustical performance.
May 21, 2025 - The Titus chilled ceiling line includes active/passive beams and floor-mounted displacement beams, delivering energy-efficient performance and enhanced thermal comfort for occupants while reducing building heating and cooling energy use.